Multi-ranging Conductivity, TDS, NaCl, Temperature Meter with 4-ring Potentiometric Conductivity Probe with Platinum Sensors - Ms 3411

 

Features
• Auto-ranging
• 4-ring potentiometric conductivity probe with internal temperature sensor
• Automatic (ATC), Manual (MTC) or No Temperature Compensation (NoTC)
• Good Laboratory Practice
• PC compatible

Overview
Ms 3411 measures Conductivity, TDS, NaCl and temperature. In extended conductivity and TDS ranges (up to 500 Ms/cm and 400 g/L respectively) the instrument automatically chooses the best scale.
This instrument utilizes a 4-ring potentiometric probe with platinum sensors that offers greater versatility over typical amperometric designs. By utilizing the 4-ring method, it is possible to measure very low or high conductivity levels without
changing probes.
Calibration is automatic at 1 point with 6 memorized buffers.
The meter has 3 options for temperature compensation: ATC between 0 to 60.0°C, MTC and NoTC.
Other features include a read lock function, stability indicator, GLP and PC compatibility via optional Ms 03111 software.

 
 
multi-ranging-conductivity-ms-3411 Microsetcontrols
 
Specifications :
 

Range: (Conductivity) 0.00 to 29.99 μS/cm; 30.0 to 299.9 μS/cm; 300 to 2999 μS/cm; 3.00 to 29.99 Ms/cm; 30.0 to 200.0 Ms/cm; up to 500.0 Ms/cm (actual Conductivity)
Range: (TDS) 0.00 to 14.99 mg/L (ppm); 15.0 to 149.9 mg/L (ppm); 150 to 1499 mg/L (ppm); 1.50 to 14.99 g/L (ppt); 15.0 to 100.0 g/L (ppt); up to 400.0 g/L (actual TDS), with 0.80 conversion factor
Range: (NaCl) 0.0 to 400.0%
Range: (Temp) -9.9 to 120.0°C
Resolution: (Conductivity) 0.01 μS/cm; 0.1 μS/cm; 1 μS/cm; 0.01 Ms/cm; 0.1 Ms/cm
Resolution: (TDS) 0.01 mg/L; 0.1 mg/L; 1 mg/L; 0.01 g/L; 0.1 g/L
Resolution: (NaCl) 0.1%
Resolution: (Temp) 0.1°C
Accuracy: (Conductivity) ±1% of reading ± (0.05 μS/cm or 1 digit)
Accuracy: (TDS) ±1% of reading ± (0.03 mg/L or 1 digit)
Accuracy: (NaCl) ±1% of reading
Accuracy: (Temp) ±0.4°C
Calibration: (Conductivity) automatic, 1 point with 6 memorized values (84, 1413,5000, 12880, 80000, 111800 μS/cm)
Calibration: (NaCl) 1 point, with Ms 8148 calibration solution
Calibration: (Temp) 2-point, at 0 and 50°C (32 and 122°F)
Temperature Compensation: automatic or manual, 0 to 60°C (32 and 140°F)
Temperature Coefficient: selectable from 0.00 to 6.00%/°C (Conductivity and TDS only)
TDS Conversion Factor: selectable from 0.40 to 0.80 (default value: 0.50)
Probe: (included) Ms 87421, 4-ring platinum, internal temperature sensor
Auto-off: after 5 minutes of non-use (can be disabled)
Power Supply: (included) 12 Vdc adapter
Environment: 0 to 50°C (32 to 122°F); RH max 95%
Dimensions/Weight: 240 x 182 x 74 mm / 1.1 kg

Product Contents
Ms 3411 is supplied with conductivity probe, power adapter and instructions.

 
 
request Microsetcontrols
pdf-button Microsetcontrols
 
line Microsetcontrols
           
   
Microsetcontrols
Microsetcontrols
Microsetcontrols  
   
 
Home

About us

Contact us

Enquiry

Sitemap
 
 
     
Industrial pH Sensor Ms pH 01 / Ms pH 02 / Ms pH 04, Ms pH 07, • pH Sensor – Industrial – HF Series Ms pH 22 / HF / Pt 100, • Industrial pH Sensor - Ms pH 36 – Flat (Origin USA), • pH Indicator Ms pH 19, • pH Controller Ms pH 27 / Ms pH 27 W, • pH Transmitter Ms pH 27 B / Ms pH 18 T, • Lab / Bench Meter Ms pH 616 / Ms pH 644, Ms 324 / Ms pH 816 / Ms 9535, • pH Sensor Housing for Fermentor Model 330, • pH Flow Cell, • Industrial ORP Sensor with Platinum Tip Ms ORP 01 / Ms ORP 02 / Ms ORP 36, • ORP Indicator Ms ORP 19, • ORP Controller Ms ORP 27 Panel Mounted, • ORP Controller Ms ORP 27 W Field Mounted
 
MICROSET CONTROLS
Microsetcontrols
:
B 404, Marvel Imperial, FP No 260/2&3, Narangibaug Road, Boat Club Area,
Pune - 411 001. Maharashtra, INDIA.
Microsetcontrols
:
Microsetcontrols
:


MICROSET CONTROLS
 

Microsetcontrols